iSimulate REALITi 360 Version 11.14.0 is Available for Download!
We’re thrilled to introduce the latest REALITi 360 update! Make sure to update your app in the AppStore today to access the newest features and latest improvements.
Full details can be found on iSimulate’s website.
Latest Improvements Include:
Atlas
- Added support for Atlas Adult Next Gen
- Implemented Atlas Baby bootloader firmware update. It will only update if there is a new firmware MCU app update.
Corpuls
- Corrected texts to “corpus simulation”
- Corrected “VT/VF possible” translation in DE for C3
- Improved metronome automatic start settings for manual defibrillator and AED, to display correct metronome setting when switching between AED and manual defibrillator
- Set the on-state default value to Adult 30:2 for the automatic start of the metronome in both manual and AED settings
CPR Band
- Updated CPR recommendation statement for CPR device renaming
- Updated renaming rule to accept only the new naming format
- Updated CPR recommendation statement for CPR device renaming – CPR sensor name should contain CPR-
Facilitator/Control
- Added a randomiser for the Arterial line to be in effect when the line is inserted while RR value is zero
- Resolved crashing when ‘HOLD TO SPEAK’ is tapped while recording
- Added a message in the User Recordings window to indicate when no recordings are saved
- Disabled the ‘HOLD TO SPEAK’ button during recording or until the recording is saved or discarded
- Added ‘HOLD TO SPEAK’ button in dark mode
- Updated UI for ‘New Recording’ menu when recording
- Added prevention on selecting other Sound categories while recording
- Changed how User Recordings and New Recording appear; selecting User Recordings now will show both together
Hamilton T1
- Resolved the issue of Neonate weight dial minimum value lowering the minimum value of Vt past the limit
- Set up the default value for parameter Rate to depend on IBW (adult) or weight (neonatal) values
- Adjusted Neo SPONT mode limits to Basic, More, and Apnea options
- Improved Neo SPONT mode values
- Resolved the issue of the Standby Screen becoming unresponsive after pressing the Power button while a parameter dial is active (orange)
- Activated Tools window button
- Initialized Tools window
- Added initial Utilities and Configuration tabs including contents
- Updated Neonatal UI options in Standby mode
- Added the three Neonatal quick setup buttons
- Created the Neonatal dial with a default of 2.0kg and allows weight adjustment
- Improved last Patient tab UI with the ability to recall the last patient data
- Corrected the default Last Patient tab on the first load of Standby
- Initialized Events window
Nihon Kohden — EMS1052 PURCHASE NOW!
- Created a simulated CPR waveform
- Added CPR waveform in AED, Manual, and Monitor modes (comp bars excluded)
- Added CPR elapsed time including how it resets when a new CPR device connection is established
- Resolved Pad messages appearing behind the CPR guide-lines
- Updated the JA text display ‘Do 5 more chest compressions. Do not touch ‘patient’ in AED by removing an unnecessary symbol
- Resolved the issue of multiple texts appearing on Press Scale options while in the JA language
- Resolved the issue of the ‘Use Disposable Pads’ voice overlap with the ‘Press AED button’
- Added restriction to the use of the charge button when Pads are off
- Resolved the issue of “CPR Assist” message appearing in Pacing even when there is no CPR assist connected
- Corrected the EN text display ‘Do 5 more chest compressions. Do not touch ‘patient’ in AED by removing an unnecessary symbol
- Resolved the issue of waveforms (EtCO2, SpO2) resetting after Send is pressed from Control
- Initialized behavior for the Alarm slider’s up and down arrows when it reaches the limit by changing it to a light grey color when they become ‘disabled’ or ‘off’
Zoll
- Resolved where Zoll monitors were experiencing crashes after switching from a different monitor with VT/VF alarms occurring before or after the switch
- Added 8-sec timer in Zoll X monitors to close defibrillator window and return to the home screen after a shock is delivered
Multiple Screens
- Resolved parameter values for vitals: HR, SpO2, ETCO2, etc. not updating correctly
Translation Improvements
- Updated Brazilian Portuguese translations
- Added adjustments to Zoll X, LifePak 15, and CPR Console to ensure Brazilian Portuguese translations fit appropriately
- Updated Simplified Chinese REALITi Translation
- Created a simulated CPR waveform
- Added CPR waveform in AED, Manual, and Monitor modes (comp bars excluded)
- Added CPR elapsed time including how it resets when a new CPR device connection is established
- Resolved Pad messages appearing behind the CPR guide-lines
- Updated the JA text display ‘Do 5 more chest compressions. Do not touch ‘patient’ in AED by removing an unnecessary symbol
- Resolved the issue of multiple texts appearing on Press Scale options while in the JA language
- Resolved the issue of the ‘Use Disposable Pads’ voice overlap with the ‘Press AED button’
- Added restriction to the use of the charge button when Pads are off
- Resolved the issue of “CPR Assist” message appearing in Pacing even when there is no CPR assist connected
- Corrected the EN text display ‘Do 5 more chest compressions. Do not touch ‘patient’ in AED by removing an unnecessary symbol
- Resolved the issue of waveforms (EtCO2, SpO2) resetting after Send is pressed from Control
- Initialized behavior for the Alarm slider’s up and down arrows when it reaches the limit by changing it to a light grey color when they become ‘disabled’ or ‘off’
Zoll
- Resolved where Zoll monitors were experiencing crashes after switching from a different monitor with VT/VF alarms occurring before or after the switch
- Added 8-sec timer in Zoll X monitors to close defibrillator window and return to the home screen after a shock is delivered
Multiple Screens
- Resolved parameter values for vitals: HR, SpO2, ETCO2, etc. not updating correctly
Translation Improvements
-
- Updated Brazilian Portuguese translations
- Added adjustments to Zoll X, LifePak 15, and CPR Console to ensure Brazilian Portuguese translations fit appropriately
- Updated Simplified Chinese REALITi Translation
Visit the App Store today to update your REALITi 360 system.
Contact the 3B Scientific & Echo Healthcare teams today for more information on any of our products or services at salessupport@echosimulation.com or +1 877-393-0499.